DSR 2023 · SH 26 · NEW TECHNOLOGIES AND

CPWD DSR item 26.93.2 rate analysis

Providing and fixing of façade at all heights with extruded hollow Clay / Terracotta ventilated rainscreen tiles of height 259/ 309/ 409mm and lengthof 1190 mm of approved texture,design and pattern having Flexural Strength/ Modulus of Rupture of ≥ 14 N/m² and maximum water absorption of 10% tested as per ISO 10545-4:2004(E) and ISO 10545-3:1995 respectively in true level fixed to a supporting aluminium framework (Alloy 6063 T5/T6) consisting of vertical 'T' (for intermediates)/ 'L' (for ends/ termination)/ Tubular sections (at corners)of size 80x60x2mm/ 40x60x2mm/ 40x40x2mm respectively, spaced at maximum spacing of 1200mm c/c matching to the tile vertical grid, and horizontal aluminium 'C'-clamps of size 56x34x2 mm thickness of length 150mm at junction of tiles and of length 75mm at wall ends/ corners fixed on top of the vertical sections at spacing of 250/ 300/ 400mm c/c matching to the tile horizontal grid with two numbers of self-drilling / self-tapping SS screws of size 5.5x25 mm with EPDM washers. The vertical 'T'/'L/ Tubular' sections shall be fixed to the wall using HDG (hot-dip-galvanized) steel L-brackets (galvanizing thickness of minimum 80 microns) of size 110x80x6 mm at intermediate vertical aluminium profiles and of size 220x110x12 mmat outer corners and stainless steel grade 304,M10 full threaded anchor fasteners with nylon sleeve 100mm long (for brick work) and M8 expansion anchor fasteners 75mm long for concrete surface, spacing of brackets to be based on a structural/ static calculation. The brackets shall be of length 175mm at junction of two vertical aluminium profiles and of length 100mm at intermediate points of vertical profiles and shall be fixed to the vertical aluminium T / L / Tubular profiles using two numbers self-drilling/ self-tapping SS screws of size 5.5x25 mm with EPDM washers. EPDM gaskets to be fixed in between brackets and vertical profiles. The tiles shall be mounted on the ‘C’ clamps such that the tiles are supported at top and bottom at both ends. The tiles shall be mounted on the C-clamps with EPDM profiles in between such that the tiles are supported at top and bottom at both ends. The vertical joint open groove between two adjacent tiles shall be 10mm. The tiles and system shall be designed to resist wind load as per IS 875 (Part 3) according to different zones. The tiles shall be installed using the ventilated rain screen principle with provision for natural ventilation of the space between the façade tiles and the structural wall. The work shall be carried out as per specification, drawing and as per direction of the Engineer-in-Charge. Note : Scaffolding wherever required to be paid separately. With 24mm thickness (+/- 10%) terracotta tiles of other than grey colors

Published rate₹5,842.50per sqm
Rate analysis

Providing and fixing of façade at all heights with extruded hollow Clay / Terracotta ventilated rainscreen tiles of height 259/ 309/ 409mm and lengthof 1190 mm of approved texture,design and pattern having Flexural Strength/ Modulus of Rupture of ≥ 14 N/m² and maximum water absorption of 10% tested as per ISO 10545-4:2004(E) and ISO 10545-3:1995 respectively in true level fixed to a supporting aluminium framework (Alloy 6063 T5/T6) consisting of vertical 'T' (for intermediates)/ 'L' (for ends/ termination)/ Tubular sections (at corners)of size 80x60x2mm/ 40x60x2mm/ 40x40x2mm respectively, spaced at maximum spacing of 1200mm c/c matching to the tile vertical grid, and horizontal aluminium 'C'-clamps of size 56x34x2 mm thickness of length 150mm at junction of tiles and of length 75mm at wall ends/ corners fixed on top of the vertical sections at spacing of 250/ 300/ 400mm c/c matching to the tile horizontal grid with two numbers of self-drilling / self-tapping SS screws of size 5.5x25 mm with EPDM washers.

DSR rate₹5,842.50per sqm

The vertical 'T'/'L/ Tubular' sections shall be fixed to the wall using HDG (hot-dip-galvanized) steel L-brackets (galvanizing thickness of minimum 80 microns) of size 110x80x6 mm at intermediate vertical aluminium profiles and of size 220x110x12 mmat outer corners and stainless steel grade 304,M10 full threaded anchor fasteners with nylon sleeve 100mm long (for brick work) and M8 expansion anchor fasteners 75mm long for concrete surface, spacing of brackets to be based on a structural/ static calculation. The brackets shall be of length 175mm at junction of two vertical aluminium profiles and of length 100mm at intermediate points of vertical profiles and shall be fixed to the vertical aluminium T / L / Tubular profiles using two numbers self-drilling/ self-tapping SS screws of size 5.5x25 mm with EPDM washers.

EPDM gaskets to be fixed in between brackets and vertical profiles. The tiles shall be mounted on the ‘C’ clamps such that the tiles are supported at top and bottom at both ends. The tiles shall be mounted on the C-clamps with EPDM profiles in between such that the tiles are supported at top and bottom at both ends. The vertical joint open groove between two adjacent tiles shall be 10mm. The tiles and system shall be designed to resist wind load as per IS 875 (Part 3) according to different zones. The tiles shall be installed using the ventilated rain screen principle with provision for natural ventilation of the space between the façade tiles and the structural wall. The work shall be carried out as per specification, drawing and as per direction of the Engineer-in-Charge.

Note : Scaffolding wherever required to be paid separately.

With 24mm thickness (+/- 10%) terracotta tiles of other than grey colors

Item code
26.93.2
Sub-head
SH 26 · NEW TECHNOLOGIES AND
Unit
sqm
Source row
5053

Cost components

CodeDescriptionUnitQuantityRateAmount
Detail of cost for 12.60 sqm (4.2 (0.3+3.6+0.3) x 3.0 metre)
MATERIAL
Façade area = 12.60 sqm + Wastage @ 5% = 0.63 sqm. Total = 13.23 sqm
5765 24mm thick extruded terracotta tiles of grey color of size 309x1190 mm and length 1190mm sqm 13.23 ₹2,320.00 ₹30,693.60
7306 Aluminium Tube / T Profile kg 12.6 ₹198.00 ₹2,494.80
1). At outer corners tubular section 40x40x2 mm = 2 nos. 3 mtr. long = 6.00 mtr. @ 0.82 kg/mtr. = 4.92 kg 2). At ends/termination angle 40x60x2 mm = 2 nos. 3 mtr. long = 6.00 mtr. @ 0.53 kg/mtr. = 3.18 kg 3). At intermediate T section 80x60x2mm = 2 nos. 3 mtr. long = 6.00 mtr. @ 0.75 kg/mtr. = 4.50 kg (Total = 4.92+3.18+4.50 = 12.60 kg)
7306 Aluminium C Clamps of size 56x34x2.0 mm kg 5.07 ₹198.00 ₹1,003.86
(i) 150mm long - 2x11 no. = 22.00 nos. x 0.15 = 3.3 mtr. @ 0.615 kg/mtr. = 2.03 kg (ii) 75mm long - 6x11=66.00 nos. x 0.075 = 4.95 mtr. @ 0.615 kg/mtr.= 3.04 kg Total=2.03 + 3.04 = 5.07 kg
7221 Self-Drilling/Self-Tapping Screws 5.5x25 mm long each 236 ₹4.00 ₹944.00
(a) Bracket to vertical profile - 30 Nos.x2.00 nos. = 60.00 Nos
b) For fixing of brackets to “C” clamps (22+66=88)x2=176 nos.
Total = 176 Nos + 60 = 236.00 Nos
1007 HDG Mild Steel Brackets (Minimum 80 microns Galvanizing) quintal 0.636 ₹5,965.00 ₹3,793.74
a) Wall bracket - 110 x 80x6mm thick
(i) 100 mm long = 10x0.10= 1.00 Mtr @ 8.65 kg/mtr. = 8.65 kg
(ii) 175mm long = 10x0.175=1.75 mtr. @ 8.65 kg/mtr. = 15.13 kg
Total = 8.65 + 15.13 = 23.85 kg
b) Corner Bracket of size 220 x 110 x 12mm thick
(a) 100mm long - 5 Nos x0.10 = 0.50 mtr. @ 28.90 Kg/mtr. = 14.45 Kg
(b) 175mm long - 5x0.175= 0.875 mtr. @ 28.90 kg/mtr. = 25.28 kg
Total = 14.45 + 25.28 = 39.73 kg
Gross total = 23.85+39.73 = 63.58 kg = 0.636 quintal
7222 SS Anchor Fasteners (RCC / Brick) – M-8x100 mm each 30 ₹76.00 ₹2,280.00
6x5 nos. = 30 Nos Bracket
7390 EPDM Gaskets of size 100x80 mm metre 3 ₹16.00 ₹48.00
30x0.10=3.00 mtr.
7218 MS Polymer Sealant Adhesive litre 0.175 ₹1,320.00 ₹231.00
Area = 12.60 Sqm + 5% = 13.23 Sqm Adhesive required = 175 ml. or 0.175 ltr.
7390 EPDM gasket for tiles mounting on C - clamps metre 8.25 ₹16.00 ₹132.00
(i) 150mm long - 2x11 no. = 22.00 nos. x 0.15 =3.3 mtr.
(ii) 75mm long - 6x11=66.00 nos. x 0.075 = 4.95 mtr.
Total = 3.3 + 4.95 = 8.25 mtr.
LABOUR
0166 Installation charges for fixing of façade at all heights with extruded hollow clay/terracotta ventillated rain screen tiles sqm 12.6 ₹736.00 ₹9,273.60
9999 Carriage of materials L.S. 125 ₹2.27 ₹283.75
9999 T&P and materials Lead & Lift L.S. 250 ₹2.27 ₹567.50

Rate build-up

TOTAL ₹51,745.85
Add 1 % Water charges on "W" ₹517.46
TOTAL ₹52,263.31
Add GST on "X" (multiplying factor 0.2127) ₹11,116.41
TOTAL ₹63,379.72
Add 15% CPOH on "Y" ₹9,506.96
TOTAL ₹72,886.68
Add Cess @ 1% on "Z" ₹728.87
Cost of 12.60 sqm. ₹73,615.55
Cost of 1 sqm ₹5,842.50
Say ₹5,842.50

Use this rate in the interactive workbook

Search, temporarily edit basic rates, recalculate dependencies, and export from the existing DSR workbook.

Open DSR Workbook